  https://www.phoenixcontact.com/pi/products/2902066 10/16/2018???page? 1 ?/? 4 power terminal block?-?mini mcr-2-ptb?-?2902066 please be informed that the data shown in this pdf document is generated from our online catalog. please find the complete data in the user's documentation. our general terms of use for downloads are valid (http://phoenixcontact.com/download) power terminal with plug-in connection technology for delivering the supply voltage to the din rail connector. monitoring of the supply voltages in combination with the fault monitoring module. screw connection technology product description the power terminal with plug-in connection technology is used to deliver the supply voltage to the din rail connector. two separate voltage inputs permit a redundant and diode-decoupled power supply up to a maximum current of 3.2 a. the fm power terminal offers the additional functions of monitoring in combination with the mini?mcr-2-fm-rc(-pt) fault monitoring module (order no.: 2904504, 2904508), the flexible, redundant supply of one or both module sides, and an extended supply voltage range of 9.6...30 v dc. the power terminal supports nfc communication. key commercial data packing unit 1 pc gtin gtin 4046356649933 technical data note utilization restriction emc: class a product, see manufacturer's declaration in the download area dimensions width 6.2 mm height 110.5 mm depth 120.5 mm ambient conditions ambient temperature (operation) -40 c ... 70 c ambient temperature (storage/transport) -40 c ... 85 c permissible humidity (operation) 5 % ... 95 % (non-condensing) output data pwr out + + + C C C C + pwr 1 in out-fm pwr 2 in out-fm pwr 2 in pwr 1 in in out fm 1 5 2 6 3 7 4 8 +9,6 v +30 v +9,6 v +30 v zone 2 in +9,6 v +30 v +9,6 v +30 v C +
https://www.phoenixcontact.com/pi/products/2902066 10/16/2018???page? 2 ?/? 4 power terminal block?-?mini mcr-2-ptb?-?2902066 technical data output data output voltage range 9.6 v dc ... 29.7 v dc general operating voltage display green led (pwr 1) green led (pwr 2) mounting position any assembly instructions the t connector can be used to bridge the supply voltage. it can be snapped onto a 35 mm din rail according to en 60715. connection data, input connection method screw connection conductor cross section solid min. 0.2 mm2 conductor cross section solid max. 1.5 mm2 conductor cross section flexible min. 0.2 mm2 conductor cross section flexible max. 1.5 mm2 conductor cross section awg min. 26 conductor cross section awg max. 16 stripping length 10 mm screw thread m3 standards and regulations electromagnetic compatibility conformance with emc directive noise emission en 61000-6-4 standards/regulations en 61000-4-2 designation electromagnetic rf field standards/regulations en 61000-4-3 en 61000-4-4 en 61000-4-5 designation conducted interferences standards/regulations en?61000-4-6 conformance ce-compliant atex ? ii 3 g ex na iic t4 gc x ul, usa/canada ul 508 listed class i, div. 2, groups a, b, c, d t6 class i, zone 2, group iic t6 fire protection for rail vehicles (din en 45545-2) r22 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r23 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r24 hl 1 - hl 2 environmental product compliance china rohs environmentally friendly use period = 50 for details about hazardous substances go to tab downloads, category manufacturer's declaration pwr out + + + C C C C + pwr 1 in out-fm pwr 2 in out-fm pwr 2 in pwr 1 in in out fm 1 5 2 6 3 7 4 8 +9,6 v +30 v +9,6 v +30 v zone 2 in +9,6 v +30 v +9,6 v +30 v C +
https://www.phoenixcontact.com/pi/products/2902066 10/16/2018???page? 3 ?/? 4 power terminal block?-?mini mcr-2-ptb?-?2902066 drawings block diagram approvals approvals approvals ul listed / cul listed / gl / culus listed ex approvals atex / ul listed / cul listed / culus listed approval details ul listed? ? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 238705 cul listed? ? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 238705 gl? ? ? http://exchange.dnv.com/tari/ ?14445-15 hh culus listed? ? ? ? pwr out + + + C C C C + pwr 1 in out-fm pwr 2 in out-fm pwr 2 in pwr 1 in in out fm 1 5 2 6 3 7 4 8 +9,6 v +30 v +9,6 v +30 v zone 2 in +9,6 v +30 v +9,6 v +30 v C +
https://www.phoenixcontact.com/pi/products/2902066 10/16/2018???page? 4 ?/? 4 phoenix contact 2018 ? - all rights reserved http://www.phoenixcontact.com phoenix contact gmbh & co. kg flachsmarktstr. 8 32825 blomberg germany tel. +49 5235 300 fax +49 5235 3 41200 http://www.phoenixcontact.com pwr out + + + C C C C + pwr 1 in out-fm pwr 2 in out-fm pwr 2 in pwr 1 in in out fm 1 5 2 6 3 7 4 8 +9,6 v +30 v +9,6 v +30 v zone 2 in +9,6 v +30 v +9,6 v +30 v C +